EndoKing Obturation Pen

The Endoking Obturation Pen System is a cordless tool designed for warm vertical compaction during root canal treatments. It applies vertical pressure to heat-softened gutta-percha, ensuring complete canal filling.

₹3,450.00
In stock
SKU
SBEN07005
Price: 3,450.00 (Inclusive of Taxable Goods)
- +
EndoKing Obturation Pen is available to buy in increments of 1

Contact us for sales assistance from our Biomedical Engineer.

Prashanth Reddy V | Senior Sales Executive

+91 9063507429

[email protected]

Features:

  • Slim, lightweight design for a comfortable grip, reducing fatigue and allowing easy handling.
  • Adjustable needle type and temperature mode for optimal gutta-percha compaction.
  • Fast heating time, reaching up to 200°C in just 3 seconds.

Heating Capability:

  • Heats up to 200°C in only 3 seconds.

Indications:

  • Ideal for vertical compaction of gutta-percha in root canal fillings, especially in the apical region.
  • Can also function as a gutta-percha cutter.

Advantages:

  • Simple, ergonomic design.
  • Adjustable needle type and temperature mode.
  • Easy to use with high sealing efficiency
Technical Details
Technical Specification

 

MODEL OP – Fill AC 220V
POWER SUPPLY AC220V, 50-60HZ
POWER 10W
PACKING SIZE 165x125x38mm
  • 1 x Obturation Pen
  • 1 x Charging Base
  • 2 x Tips ( White-45/02 & Black-50/04 )

HEAT :

  • Press the button to the heat the tip, the LED indicator light Green.
  • The tip can reach a working temperature within 3 seconds.

CHARGE :

  • Put the obturation pen onto the charging base, the LEd indicator light blue. 
  • The unit should be Continuous charged for 12 hours from low voltage to full charge.

MAINTENANCE AND STERILIZATION:

  • Clean and sterilize the pen tip before each treatment.
  • The remaining gutta-percha can be cleaned by a cotton swab.
  • Clean the exterior of the heating unit and charging base by using a soft cloth moistened with a mild detergent or rubbing alcohol.
  • The surface should be sheathed with a plastic barrier to prevent contamination and discoloration.
  • Do not use strong disinfectants or those that contain bleach or ammonium chloride to clean the device.
  • Do not autoclave the heating unit or charging base.
  • After each use, the tips should be sterilized by autoclave for 60 mins at 121 degree Celcius.

NOTE: The temperature of the tip is very high during the surgery, avoid its direct contact to the soft tissue to avoid burns.

Write Your Own Review
You're reviewing:EndoKing Obturation Pen

Contact us for sales assistance from our Biomedical Engineer.

Prashanth Reddy V | Senior Sales Executive

+91 9063507429

[email protected]

WA button WA button
Copyright © 2023-present SignelbioMedical, Inc. All rights reserved.