GC Fujicem Luting Glass Ionomer

Resin Reinforced Glass Ionomer Luting Cement

GC FujiCEM is the world's first glass ionomer luting cement mixed from pastes. The innovative Paste Pak System is engineered to simplify dispensing and enhance consistency in cementation, guaranteeing optimal results every time.

As low as ₹945.00
In stock
Only %1 left
SKU
SBGC8095

Price is inclusive of Taxable Goods

- +
GC Fujicem Luting Glass Ionomer is available to buy in increments of 1

Features:

  • Cartridge delivery ensures precise ratio dispensing.
  • Reduces cement waste.
  • Adjustable amount of dispensed cement.
  • Mixes easily in just 10 seconds.
  • No air bubbles.
  • Adequate working time.
  • Minimal film thickness of only 3 µ.
  • Assured adhesive strength.
  • Effective fluoride release.
  • Superior clinical performance.

Indications:

  • Cementing all types of metal, porcelain-fused-to-metal, and resin crowns, inlays, onlays, and bridges
  • Cementing porcelain inlays
  • Used as a base or liner

Advantages:

  • Cartridge delivery ensures precise ratio dispensing.
  • Reduces cement waste.
  • Adjustable amount of dispensed cement.
  • Mixes easily in just 10 seconds.
  • No air bubbles.
  • Adequate working time.
  • Minimal film thickness of only 3 µ.
  • Assured adhesive strength.
  • Effective fluoride release.
  • Superior clinical performance.
Technical Details
Technical Specification

COMPOSITION

PASTE A %by wt PASTE B % by wt
Aluminosilicate glass 60-70 distilled water 30-40
2-Hydroxyethyl methacrylate 10-20 polyacrylic acid 30-40
Urethane dimethacrylate 10-12 benzenosulfonic acid sodium salt 2-3
Silica powder 6 Silica Powder 2
Camphorquinone <1%    

 

mixing time no. of crowns
10 sec single crown
15 sec 2-4 crowns

 

working time setting time
3 min 4min30sec


Note: Refrigeration of cartridges extends the working time by 30 sec

CONTRAINDICATIONS

1. Pulp capping.

2. In rare cases the product may cause sensitivity in some people. If any such reactions are experienced, discontinue the use of the product and refer to a physician.

STORAGE

Store in a cool and dark place (4-25°C)(39.2-77.0°F). If not in use for a prolonged period of time, store in refrigerator.

Shelf life: 2 years from the date of manufacture

Product Components

Gc Fujicem Refill Pack 13.3g Cartridge:

  • 1 Cartridge of 13.3 gm / 7.2 ml
  • Instruction Manual
  • 1 x Mixing Pad

Gc Fujicem Luting Glass Ionomer - Dispenser:

  • 1 x Dispenser only
Directions to Use

1. Loading the Paste Pak Cartridge

a. Ensure the piston is fully retracted into the dispenser.

Note: To retract the piston, grip both the slide block and release lever (located on the underside of the dispenser) with your fingers and pull them back together.

b. Load the cartridge into the Paste Pak Dispenser.

  1. Align the mark on the cartridge with the mark on the Paste Pak Dispenser as shown.
  2. Turn the cartridge fully to the right position.

Note: To remove the cartridge, retract the piston completely and turn the cartridge back to the marked position.

c. After loading the cartridge, slide the release lever forward until it stops.

  1. Push the front of the release lever.
  2. Do not push the upper side.

2. Dispensing

a. Remove the cartridge cover.

b. Press the lever to dispense the required amount of paste onto the mixing pad.

Note:

  1. Before dispensing material from a new cartridge or after a long interval, bleed the pastes to prevent air bubbles.
  2. The finger grip can be moved forward or backward to adjust the amount of material dispensed.

c. While pressing the lever, level and cut off the extruded material from the cartridge tips by moving the cartridge and dispenser to an upright position on the mixing pad.

  1. Level and cut off material.
  2. Depress the lever. When the lever is released after dispensing, residual pastes at the tips are retracted into the cartridge. Replace the cartridge cover.

Note:

  1. If surplus paste remains on the cartridge tips after dispensing, remove it with gauze or similar material.
  2. The amount of residual material in the cartridge can be checked by the position of the slide block on the underside of the dispenser. The translucent tips of the cartridge also allow the position of the inner plunger to be seen.
  3. Do not drop the dispenser with the cartridge, as it may cause damage.

3. Mixing

After dispensing, spread the material in a thin layer on the mixing pad using a plastic spatula. Mix thoroughly with lapping strokes for 10 seconds, avoiding the incorporation of air bubbles.

Note:

  1. The two pastes are similar in color, so mix carefully. When a larger amount is needed for 2-4 crowns, mix for 15 seconds.
  2. The working time is 3 minutes from the start of mixing at 23°C (73.4°F). Higher temperatures will shorten the working time.
  3. Do not mix GC FujiCEM pastes with other materials.
Write Your Own Review
You're reviewing:GC Fujicem Luting Glass Ionomer

Gc Fujicem Refill Pack 13.3g Cartridge:

  • 1 Cartridge of 13.3 gm / 7.2 ml
  • Instruction Manual
  • 1 x Mixing Pad

Gc Fujicem Luting Glass Ionomer - Dispenser:

  • 1 x Dispenser only

1. Loading the Paste Pak Cartridge

a. Ensure the piston is fully retracted into the dispenser.

Note: To retract the piston, grip both the slide block and release lever (located on the underside of the dispenser) with your fingers and pull them back together.

b. Load the cartridge into the Paste Pak Dispenser.

  1. Align the mark on the cartridge with the mark on the Paste Pak Dispenser as shown.
  2. Turn the cartridge fully to the right position.

Note: To remove the cartridge, retract the piston completely and turn the cartridge back to the marked position.

c. After loading the cartridge, slide the release lever forward until it stops.

  1. Push the front of the release lever.
  2. Do not push the upper side.

2. Dispensing

a. Remove the cartridge cover.

b. Press the lever to dispense the required amount of paste onto the mixing pad.

Note:

  1. Before dispensing material from a new cartridge or after a long interval, bleed the pastes to prevent air bubbles.
  2. The finger grip can be moved forward or backward to adjust the amount of material dispensed.

c. While pressing the lever, level and cut off the extruded material from the cartridge tips by moving the cartridge and dispenser to an upright position on the mixing pad.

  1. Level and cut off material.
  2. Depress the lever. When the lever is released after dispensing, residual pastes at the tips are retracted into the cartridge. Replace the cartridge cover.

Note:

  1. If surplus paste remains on the cartridge tips after dispensing, remove it with gauze or similar material.
  2. The amount of residual material in the cartridge can be checked by the position of the slide block on the underside of the dispenser. The translucent tips of the cartridge also allow the position of the inner plunger to be seen.
  3. Do not drop the dispenser with the cartridge, as it may cause damage.

3. Mixing

After dispensing, spread the material in a thin layer on the mixing pad using a plastic spatula. Mix thoroughly with lapping strokes for 10 seconds, avoiding the incorporation of air bubbles.

Note:

  1. The two pastes are similar in color, so mix carefully. When a larger amount is needed for 2-4 crowns, mix for 15 seconds.
  2. The working time is 3 minutes from the start of mixing at 23°C (73.4°F). Higher temperatures will shorten the working time.
  3. Do not mix GC FujiCEM pastes with other materials.

Contact us for sales assistance from our Biomedical Engineer.